전자 부품 유통
UQDLS-08HSH04-L000: 커넥터 성능 및 사양 보고서
2026-08-29

The UQDLS-08HSH04-L000 is a socket/receptacle style quick-disconnect designed for liquid-cooling and thermal-management systems. Key cited metrics — a 5/8" hose barb, flat-face valve, stainless-steel body, and an operating range of -40°C to +105°C — drive its value where thermal stability, low leak risk, and serviceability matter. This report focuses on connector performance and practical specs engineers should verify during selection and procurement to minimize downtime and maximize thermal consistency.

1 — Product Background & Key Specs

UQDLS-08HSH04-L000: Connector Performance & Specs Report

1.1 Key specs at-a-glance

ItemValue
ModelUQDLS-08HSH04-L000
Form factorSocket / Receptacle (flat-face)
Hose connection5/8" hose barb
Body materialStainless steel
Nominal dimensionsØ ~30.5 mm, length ~86.6 mm (nominal)
Valve faceFlat-face
Seal typeElastomer O-ring / flat-face gasket

Use this quick-reference specs table to align procurement requirements and engineering checklists; confirm exact dimensions and materials with the supplier datasheet before ordering.

1.2 Design features that affect field performance

The socket operates push-to-connect or manual-actuated mating with an ergonomically positioned release control and locking detent. Flat-face valves minimize trapped volume and reduce drip on disconnects; color-coded rings provide rapid identification in dense racks. Tool-less serviceability speeds field swaps but buyers should verify O-ring replacement accessibility and spare-part kits to reduce mean time to repair (MTTR).

5/8" HOSE BARB STAINLESS BODY FLAT-FACE FLOW

2 — Measured Connector Performance & Test Data

2.1 Thermal & hydraulic performance benchmarks

Rated operating temperature range is -40°C to +105°C; this range constrains compatible coolant choices and seal material selection. For a 5/8" barb expect practical flow ranges of roughly 3–12 L/min depending on system head; specify flow-at-pressure (e.g., 5 L/min at 20 psi) and measure pressure drop across the connector. Typical recommended measurements: flow at X psi, ΔP at system flow, and thermal conductance when mounted to a cold plate to quantify thermal impact.

Recommended test metricRequest / Measure
Flow vs. pressureFlow at 10, 20, 30 psi (L/min)
Pressure dropΔP at operational flow (psi or kPa)
Thermal resistanceConnector thermal conductance (W/K) when installed

2.2 Durability, leak and environmental testing

Acceptable QA thresholds should include defined mate/unmate cycle life (for example, ≥500 cycles), maximum allowable leak rate (e.g., ≤0.1 mL/min under static conditions), and corrosion resistance consistent with stainless-steel expectations. Request temperature-cycle results, salt-spray or corrosion screening where relevant, and accelerated life testing data. Insist on test method descriptions so pass/fail criteria are traceable in incoming inspection.

3 — How to Evaluate Compatibility & Installability

3.1 Mechanical fit and hose/assembly considerations

Verify hose ID matches barb nominal ID; for a 5/8" barb confirm inner-diameter tolerance and engagement depth. Use clamps or crimp rings rated for the coolant and pressure; verify required clearance for mating/unmating and panel cutouts to avoid interference. Installers should confirm barb engagement depth, clamp torque or crimp specification, and ensure orientation allows service access without hose kinking.

3.2 System-integration checklist

Signoff AreaMust-check Item
MechanicalPanel cutout, mating clearance, retention torque
HydraulicHose ID/OD match, clamp type, leak test pass criteria
ThermalCold-plate port compatibility, thermal conductance estimate
MaintenanceService access, color coding, spare parts

Use the table above as a concise integration signoff to ensure installations meet mechanical, hydraulic, thermal, and maintenance requirements before system commissioning.

4 — Typical Use Cases & Comparative Scenarios

4.1 Common applications and operational contexts

Common deployments include cold plates in edge servers, high-density compute racks, and lab instrumentation where compact connectors and low leak risk are priorities. In edge servers, compact footprint and quick serviceability reduce rack downtime; in lab setups, predictable leak behavior and easy reconfiguration are often more important than lowest possible pressure drop.

4.2 Trade-offs and comparisons vs. alternative connector types

Flat-face push-to-connect sockets trade slightly higher initial cost for reduced drip volume and faster service versus threaded or compression fittings. Stainless-steel bodies offer superior corrosion resistance at higher weight and cost than plastic alloys; choose UQDLS-08HSH04-L000-like fittings where durability and low leak risk are prioritized over ultimate weight savings.

5 — Procurement & Field-Testing Recommendations

5.1 Pre-purchase and incoming inspection checklist

  • Confirm datasheet specs: operating temp range, maximum working pressure, materials, and exact dimensions (specs).
  • Run sample physical checks: leak test under pressure, mate/unmate cycle test to specified cycles, flow/ΔP measurement at defined flow points.
  • Request documentation: detailed test reports, material certificates, and lot traceability for each shipment.

Embed these items into RFQs and incoming inspection plans so acceptance is binary and repeatable.

5.2 Writing unambiguous specs for procurement and QA

Sample acceptance clause (copy-ready): "Supplier shall provide part UQDLS-08HSH04-L000 with material certificates and test reports. Acceptance requires no visible leakage at 1.5× working pressure, ≤0.1 mL/min static leak rate, and successful completion of 500 mate/unmate cycles. Lot traceability and packaging labels must be supplied. Nonconforming lots will be rejected."

Summary

  • The UQDLS-08HSH04-L000 form factor balances low trapped volume and serviceability; verify operating temperature, hose barb size, and seal material compatibility before selection to ensure thermal stability and low leak risk.
  • Measure connector performance by specifying flow-at-pressure, pressure-drop, and thermal conductance when mounted; require documented test procedures and traceable results in RFQs.
  • Use a procurement checklist that mandates datasheet confirmation, sample leak and cycle testing, and material certs to prevent field failures and simplify acceptance decisions.

Request the supplier datasheet and test reports and run the outlined acceptance checks before bulk purchase to minimize integration risk and downtime.

FAQ

What acceptance tests should be required for a liquid-cooling quick-disconnect?

Require documented static leak tests at 1.5× working pressure, dynamic leak verification after mate/unmate cycling, flow vs. pressure curves, and a minimum mate/unmate cycle life (e.g., 500 cycles). Ensure test methods and instruments are specified so results are comparable between suppliers.

How does flat-face valve design affect leak risk and serviceability?

Flat-face valves reduce trapped volume between connectors and minimize drip during disconnects, improving safety in dense equipment racks. They simplify service by eliminating the need to purge trapped fluid, but require precise seal surfaces to maintain low leak rates under repeated cycles.

What documentation should procurement demand for incoming inspection?

Demand full datasheets with dimensional drawings, material certifications for wetted parts, detailed test reports showing leak and cycle performance, and lot traceability. Include clear pass/fail criteria in the purchase order to avoid ambiguous acceptance decisions.

What is the operating temperature range of the UQDLS-08HSH04-L000?

The operating temperature range is -40°C to +105°C; this range constrains compatible coolant choices and seal material selection.